  • Semtech SX1262 Engine
  • Excellent blocking immunity
  • Low receive current
  • Detect channel motion to set power-saving CAD reception mode on
  • High sensitivity
  • Control easily by AT commands
  • Built-in antenna
  • AES128 Data encryption

The RYLR907 transceiver module feature the Lora long range modem that provides ultra-long range spread spectrum communication and high interference immunity whilst minimising current consumption.

Item Min. Typical Max. Unit Condition
VDD Power Supply 2 3.3 3.6 V VDD
RF Output Power Range -4 22 dBm
Filter insertion loss 1 2 3 dB
RF Sensitivity -148 dBm
RF Input Level 10 dBm
Frequency Range 820 868/915 960 MHz
Frequency Accuracy ±2 ppm
Communication Range KM Depend on RF parameter
Transmit Mode Current 140 mA RFOP = +22dBm
Receive Mode Current 10.4 mA AT+MODE=0, AT+RXBOOST=1
9.9 mA AT+MODE=0, AT+RXBOOST=0
CAD Mode

Receive Current

2.3 mA AT+MODE=2
Sleep Current 0.5 uA AT+MODE=1
Digital Input Level High 0.7*VDD VDD V VIH
Digital Input Level Low 0 0.3*VDD V VIL
Digital Output Level High 0.9 VDD V VOH
Digital Output Level Low     0.1 V  VOL
Cycling (erase / write)

EEPROM data memory

300 K  Cycles
Weight 7 g
Operating Temperature -40 25 +85 ˚C